US3 | Directory | Products Home
 

FLO - DAR Sensor Model 400 SR (Short Range)

FLO - DAR Sensor Model 400 Short Range


Call For Pricing

(714) 564-3494


 
 

The FLO-DAR™ flowmeter provides the user with highly accurate flow measurements under a wide range of flows and site conditions such as:

Shallow flow
High velocities
Flows with high solid content
Caustic flows
High Temperatures Flows
Large sewers

Product Details :

The Flo-Dar Family of flowmeters provides a revolutionary approach to open channel flow monitoring. Flo-Dar combines digital Doppler radar velocity-sensing technology with ultrasonic pulse echo level sensing to remotely measure open channel flows.

The FLO-DAR™ sensor is positioned above the flow thereby avoiding all the problems associated with traditional flowmeters when the sensor is immersed in the flow.
The model 4000SR can be fixed up to 1.5 meter above the water surface.

Benefits of the FLO-DAR™ flowmeter include:

Personnel have no contact with the flow
One-time entry into confined space for installation/removal
Easy installation
Maintenance caused by immersed sensor is eliminated

Flo-Dar Sensor with Flo-Station Electronics Specification


Permanent Flo-Dar Sensor with Flo-Station Electronics
(with Display or without Display) / (12 VDC or AC Powered)
Data Storage

64K (16K cycles of velocity/level data)

Local Terminal

RS232C @ 19.2K baud

Optional Display (Models 1101-3 and 1101-4)

Dimensions

1” x 3” Four lines of text display, FLOW, LEVEL, VELOCITY, TOTAL or any combination of any
four channels containing data. Screens may be programmed to alternate values displayed.


Timebase Accuracy

1 second per day

Outputs

Four 4-20 mA outputs; system-isolated, up to 600 load. Each output is selectable between
FLOW, LEVEL, VELOCITY OR SURCHARGE LEVEL.

Contact Closure

Dry contact closure with adjustable duration selectable for flow-proportional or alarm based on:
FLOW, LEVEL, VELOCITY, SURCHARGE LEVEL, TEMPERATURE, BATTERY VOLTAGE, EACH SAMPLE,
BAD SAMPLE or ANALOG INPUT.
Rating: 1A @ 30VDC (resistive) 0.5A @ 125 VAC (resistive)


Power Requirements

AC: 100-240 VAC, 47-63 Hz, 15 Watts (20 watts with display; backlight ON)
DC: 8 to 14.4 VDC, 15 Watts


Housing

Material: ABS Plastic, NEMA 4
Dimensions: 10.2” W x 9.3” H x 4” D (25.9 cm W x 23.6 cm H x 10.2 cm D)
Weight: 5 lbs.
Temperature Operating Range: 14° F to 122° F
(-10° C to 50° C)
Temperature Storage Range:
(without display) -40°F to 140°F (-40°C to 60°C)
(with display) 4°F to 140°F (-20°C to 60°C) w/Display


Set-Up/Data Retrieval

Flo-Ware for Windows software is the user on-site set-up, data management, and report generation software. It is compatible with desktop/portable computers utilizing Windows 95 / 98 / 2000 / Me / NT / XP. Flo-Ware for Windows software can retrieve data from both Flo-Tote and Flo-Dar Flowmeters. Flo-Ware FX for the PocketPC has all of the same functionality as Flo-Ware for Windows with the exception of report generation.

Flo-Dar Sensor Specification
All Models

Enclosure

Material: Polystyrene
Dimensions: 6.9" W x 16.65" L x 11.7" D
(17.5 cm x 42.3 cm x 29.7 cm)
Weight: 10.5 lbs (4.8kg)
Temperature Operating Range: 14° F to 122° F (-10° C to 50° C)
Storage Range: -40° F to 140° F (-40° C to 60° C)
Sensor Cable Material: Polyurethane jacketed Standard Length: 30' (9.14m), maximum 1000' (304.8 m) Disconnectable at both sensor and monitor
Velocity Measurement

Method: Radar Range: 0.75 to 20 ft/s (0.23 m/s to 6.10 m/s)
Accuracy: ±0.5%; ±0.1 ft/s (±0.03 m/s)
Level Measurement

Method: Ultrasonic
Standard Operating Range: 0.25 to 60 in. (0.634 to 152.4 cm)
Optional Operating Range: 0 (0 cm) to 224 in. (5.7 m) (with 16" deadband)
Temperature Compensated
Accuracy: ±0.25 in. (±0.64 cm) 1% Accuracy
Surcharge Level Measurement

Method: Piezo-resistive pressure transducer
Maximum Range: 138 inches (3.5 meters)
Flow Measurement

Based on Continuity Equation. Accuracy: ±5.0% of reading typical where flow is in a channel with uniform flow conditions and is not surcharged.





 
image